Brand: scuvette. 10mm quartz IR cuvette four-way 3.5mL with PTFE solid stopper, suitable for volatile-sample, sealed liquid experiments and FTIR infrared spectroscopy. Japanese fused JGS3 quartz, one-piece fused molding (high transmittance >83%; comparable to German original imports), 260nm-3500nm wavelength, max operating temp ≤600°C. Overall height with stopper 55 mm (12.5 × 12.5 × 45 mm without stopper). Wall thickness 1.25 mm. PTFE solid stopper pre-installed (included).
Brand: scuvette. 10mm quartz IR cuvette four-way 3.5mL with PTFE solid stopper, suitable for volatile-sample, sealed liquid experiments and FTIR infrared spectroscopy. Japanese fused JGS3 quartz, one-piece fused molding (high transmittance >83%; comparable to German original imports), 260nm-3500nm wavelength, max operating temp ≤600°C. Overall height with stopper 55 mm (12.5 × 12.5 × 45 mm without stopper). Wall thickness 1.25 mm. PTFE solid stopper pre-installed (included).
| Brand | scuvette |
|---|---|
| Name | Quartz IR cuvette four-way, with PTFE solid stopper |
| Path Length | 10 mm |
| Volume | 3.5 mL |
| Material | Japanese fused JGS3 quartz |
| Technology | One-piece fused molding (high transmittance >83%; comparable to German original imports) |
| Chemical Resistance | Acid, alkali and organic solvent resistant |
| Wavelength Range | 260 nm – 3500 nm |
| Window Configuration | Four-sided clear (four-way light path) |
| Stopper / Seal | PTFE solid stopper, sealed — suitable for volatile / sealed liquid samples |
| Overall Height with Stopper | 55 mm |
| Outline Dimensions | 12.5 × 12.5 × 45 mm (without stopper) / 55 mm length (with stopper) |
| Stopper Material | PTFE solid stopper (included, pre-installed) |
| Max Operating Temp | ≤600°C |
| Type / Grade | High Transmittance |
| Suitable For | FTIR infrared spectroscopy; volatile-sample / sealed liquid experiments |
| Packaging | Plastic box (1 pc), outer carton |
| Wall Thickness | 1.25 mm |
| Transmittance | >83% (260-3500 nm) |
It is made of JGS3 infrared-grade fused quartz and covers 260 nm to 3500 nm, which spans the near-UV, visible, near- and mid-infrared bands used in FTIR spectroscopy. Use it with volatile or sealed liquid samples thanks to the pre-installed PTFE stopper seal.
Yes. The solid PTFE stopper is pre-installed as a seal, so the cell is ready for volatile samples and sealed liquid experiments straight out of the box. Overall height with the stopper is 55 mm (12.5 x 12.5 x 45 mm without it).
Path length is 10 mm and the cell holds 3.5 mL. Four sides are clear, so the same cell can be used in instruments that read from different orientations.
Maximum operating temperature is 600 °C for the JGS3 body. Note that the PTFE stopper has a far lower temperature limit, so remove it before any high-temperature work.