Démontable Quartz Cuvettes for Poudre Fluorescence

Ouvert Démontable Cuvettes for Poudre and solid-Échantillon Fluorescence. JGS1 Silice fondue Fenêtres Avec a thin spacer define the Trajet optique; the Couvercle Verre presses the Échantillon Plat for reproducible Fluorescence Mesures on Edinburgh, Hitachi and similar Spectrophotomètres. Choisir glue-bonded Cuvettes for Standard Neutre Échantillons, or optically bonded Cuvettes for Élevé Chimique and Thermique Résistance.

Demountable quartz cuvette glue bonded

Démontable Quartz Cuvette — Glue Bonded

0.1–2 mm Trajet optique, 30–600 µL, JGS1 Silice fondue Avec Couvercle Verre and Optionnel aluminum Support. For Poudre Fluorescence on Edinburgh / Hitachi Spectrophotomètres.

$10.00 – $190.00 / pc

Voir Produit →
Demountable quartz cuvette optically bonded

Démontable Quartz Cuvette — Optically Bonded

0.1–2 mm Trajet optique, 30–600 µL, JGS1 Silice fondue Avec Couvercle Verre and Optionnel aluminum Support. Optique-Contact Liaison for Acide, Alcali, Organique Solvant and Élevé-Température use. For Poudre Fluorescence on Edinburgh / Hitachi Spectrophotomètres.

$10.00 – $320.00 / pc

Voir Produit →

How Poudre Fluorescence Cuvettes Work

The Échantillon Poudre is placed on the Inférieur JGS1 Silice fondue Fenêtre, the spacer defines the Longueur du trajet optique, and the Couvercle Verre gently presses the Poudre Dans a Plat, optically reproducible layer. Excitation Lumière passes À travers the Cuvette at right angles to the Fluorescence emission Trajet optique. The Optionnel Noir anodized aluminum Support lets the Cuvette stand vertically in Standard 12.5 × 12.5 mm Cuvette compartments.

Poudre Fluorescence Applications

Ces Démontable Cuvettes are designed for solid-state and Poudre Fluorescence Où the Échantillon must be recovered Après Mesure. Typique uses include:

Échantillon Manipulation & Nettoyage

Use Seulement Neutre, dry powders or soft solids. The Adhésif Liaison is not Résistant to Fort Acides, Alcalis, hydrofluoric Acide or La plupart Organique Solvants. Après use, remove the Couvercle Verre, tap out the Poudre, and Propre Les deux Fenêtres Avec lens tissue or a soft cloth. Store Fenêtres separated to avoid scratching.

Frequently Asked Questions

How do I assemble a Poudre Fluorescence Cuvette?

Place the Inférieur Fenêtre on a Plat Surface, add the spacer, deposit the Poudre Échantillon, and lay the Couvercle Verre on Haut. If using the aluminum Support, insert the assembly and stand it vertically in the Échantillon Compartiment. Avoid over-tightening, Lequel can crack the Fenêtres.

Can Ce Cuvette be Utilisé for liquid Échantillons?

No. The glue-bonded Démontable Cuvette is Ouvert on the sides and is intended for Neutre dry powders or soft solids Seulement. For liquid Échantillons, use Notre Standard Quartz Micro Cuvettes or Cellules à flux.

Lequel Instrument Marques are Ces Compatible Avec?

The Optionnel aluminum Support is sized for Standard 12.5 × 12.5 mm Cuvette compartments and is commonly Utilisé Avec Edinburgh and Hitachi Fluorescence Spectrophotomètres. Contactez-nous if Vous need a Personnalisé Support Géométrie.